Watlow EZ-ZONE
®
RMC Module 5 Chapter 1 Overview
Introduction
The EZ-ZONE
®
Rail Mount Control module (RMC)
takes the pain out of solving your thermal loop re-
quirements whether it be for a single loop, multi-loop,
stand-alone or distributed control applications.
It just got a whole lot easier to solve the thermal
requirements of your system. The RMC module is
provided in a space-saving, rail-mount package and
is highly scalable where you only pay for what you
need. For those applications that require the ability
to configure/monitor the control over a network, Mod-
bus RTU communications is an option. Other commu-
nications protocols are also available (e.g., EtherNet/
IP, DeviceNet, Modbus TCP and Profibus DP) when
used in conjunction with an RM Access (RMA) mod-
ule or when using a Remote User Interface/ Gateway
(RUI/GTW).
Standard Features and Benefits
Integrated PID and over/under safety limit con-
troller in one package
Provides two mounting options (DIN rail, chassis
mount)
Reduces wiring time and termination complexity
compared to connecting discrete products
Reduces panel space and installation cost
Increases user and equipment safety for over/under
temperature conditions
Integrated power controller output
Includes the patented NO-ARC, which drives up to
15 amp resistive loads directly
Reduces component count and cost of ownership
Saves panel space and simplifies wiring
Current monitoring (traditional or algorithm)
Detects heater current flow and provides alarm
indication of a failed output device or heater load
For use in single phase loads
Communication Capabilities
Supports network connectivity to a PC or PLC
Watlow Standard Bus or Modbus
®
RTU
Provides plug and play capabilities with Remote
User Interface (RUI’s) and RMA module
Free standard bus communications port and free
PC software (EZ-ZONE Configurator)
Additional Control Integration Options
Provides a sequencer function
Includes programmable timer functions
Includes programmable counter functions
Allows for simple math and logic programming op-
tions
Advanced PID Control Algorithm
Offers TRU-TUNE
®
+ adaptive control to provide
tighter control for demanding applications
Provides auto-tune for fast, efficient startup
Integrated Thermal Loop Diagnostics
Users can easily tell that the entire thermal sys-
tem is functioning properly
Provides complete system diagnostics that are far
superior to simple discrete level diagnostics
Allows for flexible synergistic use of hardware,
such as using one loop's sensor as a backup to an-
other loop in the event of sensor failure.
Helps prevent load loss or allow for maintenance to
be scheduled when more convenient.
Provides notification of system problems to help
reduce maintenance and service costs
Off-the-Shelf Designed System Solution
Improves system reliability with a factory integrat-
ed solution that minimizes inter-module connec-
tions and potential problems at screw termination
points.
Reduces installation cost
Eliminates compatibility headaches often encoun-
tered with using many different components and
brands
Controller Handles High Ambient Tempera-
tures
Operates in an unprecedented temperature range
of -18 to 65°C (0 to 149°F) for cabinets and panel
enclosures with elevated temperature levels
Memory for Saving and Restoring User-Defined
Parameter Default Settings
Allows customers to save and restore their own de-
fined defaults for machine parameter settings
Reduces service calls and downtime due to inad-
vertent end user parameter adjustments
RMC Modules Allow for Greater Design Flex-
ibility
Allows PID loops to be added in increments of one.
Saves money because you do not pay for any more
than you need and don’t settle for any less func-
tionality than you need
Synergistic Module Control (SMC)
Allows outputs selected for control (heat/cool),
alarms or events to be located in any physical mod-
ule, regardless of which module is connected to the
input sensor