Using This Retrofit Guide
This document is best viewed with Adobe Reader 6.0. To obtain the latest version of Adobe Reader, visit
http://www.adobe.com
Specification sheets on Watlow product may be obtained at http://www.watlow.com/literature/specsheets/
User Manuals on Watlow product may be obtained at http://www.watlow.com/literature/prodtechinfo/
Additional information on other Watlow products may be obtained by visiting http://www.watlow.com/
To locate a controller, search on the part number such as 965A-1CD0-00RG. Use the Help feature in Adobe Reader on
how to search documents.
If there are multiple listings, then the retrofit is conditional upon field use. Select the appropriate selection. The User’s
Manual is included at the bottom of this document when available.
Before selecting a replacement controller:
1. Know the application.
Temperature range
Sensor type
Is the sensor upgradable if required?
Additional input requirements – remote set points, secondary sensor or events
Output required – control, alarm, event
Is the power-switching device upgradable?
Operating voltage of controller
Mounting requirements – panel space
Is a safety limit device required?
2. Know the product.
Inputs – type and number of
Control function – direct (cool) or reverse (heat)
Outputs – switched DC, SSR, or mechanical relay
Communication requirements
Which control features are required? (cascade, slidewire, differential, remote control, other)
3. Use your best judgment for selecting a replacement controller. All applications require close examination of input,
output and the control mode needs to have the controller function properly.
4. Safety: Remember to make sure all redundant safety equipment is in place and working when retrofitting equipment.
If a system has been retrofitted without the proper safety equipment, you could be liable if an accident occurs.
This is only a guide to replacement controllers. If you have doubts, please call (507) 454-5300
and ask for technical support or email wintechsupport@watlow.com. We’re here to help. The
suggested replacement will differ in fit and form. Please review the replacement controller
specifications for suitability. Carefully check the notes for additional information that may
apply.
Your comments or suggestions on the Retrofit Guide are welcome. Please send comments or corrections to: Technical
Writer, Watlow Controls, 1241 Bundy Boulevard, P.O. Box 5580, Winona, MN 55987-5580; phone (507) 454-5300; fax
(507) 452-4507.
This Retrofit Guide is copyrighted by Watlow Winona, Inc., © February 2004 with all rights reserved. (1455)
Seitenansicht 0
1 2 3 4 5 6 ... 12 13

Inhaltsverzeichnis

Seite 1 - Using This Retrofit Guide

Using This Retrofit GuideThis document is best viewed with Adobe Reader 6.0. To obtain the latest version of Adobe Reader, visithttp://www.adobe.comSp

Seite 2

2.62(67)PressureConnector"A"2.18(55)1.88(48)(5).20 Dia.Mtg Hole2.13(54)2.50(64)1 Pole (7).27 Dia.Mtg. Hole5.70(145)4.70(119)2.79(71).27(7)Wi

Seite 3

Temperature Control Output to MDR Coil InputPlease refer to the Field Coil Power Requirements when selecting the correct temperature control output.Ex

Seite 4

HG _ _ - _ _ _ _ - 0 0 _ _Amperage30 = 30 Amp35 = 35 Amp50 = 50 Amp60 = 60 Amp80 = 80 Amp1M = 100 Amp2M = 150 AmpCoil Voltage1 = 120V~ (ac)4 = 24V~ (a

Seite 5

Model Number HG30-XKDX HG30-XAAX HG35-XLDX HG50-XMDX HG60-XPDX HG80-XABX HG1M-XACX HG2M-XADXContact Type N.O. N.O. N.O. N.O. N.O. N.O. N.O. N.O.Maximu

Seite 6

Abbreviation & Terminology(as used in this document)0.5 – 0.5 amperes of current switching capability2A – 2 amperes of current switching capabilit

Seite 7

Integral – the set point in integral (on board) to the controller.JIS – Joint Industrial Standards, a set of technical, scientific and dimensional sta

Seite 8 - User’s Manual

VTB Sw DC – Variable Time Base Switched Direct Current, a time proportioning DC output where the cycle time isvariable.

Seite 9

These notes are used to signify areas of concern in changing to a retrofit choice. These notes are also printed at the endof the retrofit listing.Note

Seite 10 - Dimensions

MDR to Solid State Alternatives Cross ReferenceHG Series Watlow Part NumberDurakool Equivalent Product Description Potential Solid State AlternativesH

Seite 11 - Field Coil Power Requirements

MDR to Solid State Alternatives Cross ReferenceHG Series Watlow Part NumberDurakool Equivalent Product Description Potential Solid State AlternativesH

Seite 12 - HG _ _ - _ _ _ _ - 0 0 _ _

HG SeriesMercury Displacement RelayWMDR-XUMN-1097June 1997Supersedes: WMDR-XUMN Rev A00 Made in the U.S.A.Printed on Recycled Paper 10% Postconsumer W

Seite 13 - Specifications WMDR-XSPN-1098

3.25(83)2.16(55).25Typ.(6)Up3.14(80)MountingSlotFor #8 To#10 Screw3.75(95)#10-32 BindingHead ScrewUp To #10A.W.G.3.43(87)Dimensions1.19(30)"A&quo

Kommentare zu diesen Handbüchern

Keine Kommentare