Watlow CLS200 Bedienungsanleitung Seite 198

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 251
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 197
Chapter 9: Troubleshooting and Reconfiguring CLS200 Series User’s Guide
182 Watlow Anafaze Doc.# 0600-3050-2000
CLS204 and CLS208 Voltage Inputs
For each voltage input on a CLS204 and CLS208 controller
you must install two resistors. The resistances must be cor-
rect for the expected input range. Note the resistor pack
(RP) locations have three through holes. Install the RD re-
sistor as indicated in the illustration below.
Table 9.8 Resistor Values for CLS204 and
CLS208 Voltage Inputs
Resistor tolerance: ±0.1%
Table 9.9 Resistor Locations for CLS204 and
CLS208 Voltage Inputs
Resistor Values
Input Range RC RD
0 to100mV
Î (dc)
499 750
0 to 500mV
Î
(dc)
5.49 k 750
0 to 1V
Î (dc)
6.91 k 442.0
0 to 5VÎ (dc)
39.2 k 475.0
0 to 10VÎ (dc)
49.9 k 301.0
0 to 12VÎ (dc)
84.5 k 422.0
Resistor Locations
Loop RC RD
1
R58 RP1
2
R56 RP2
3
R54 RP3
4
R52 RP4
5
R50 RP5
6
R48 RP6
7
R46 RP7
8
R44 RP8
RP#
RD