Series 146
Series 146
Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146E-1611-3P00 120 VAC K t/c 0 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5LW 0000 0600 A 2, 6, 8
146E-1611-3S00 120 VAC K t/c 32 to 1112°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5KW 0032 1112 A 2, 6, 8
146E-1611-3S00 120 VAC K t/c 0 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5LW 0000 0600 A 2, 6, 8
146E-1611-4000 120 VAC K t/c 32 to 1112°F Low Limit
Auto Reset
8A Relay Integral DIN Rail LV C6KZ 0032 1112 A 6, 8
146E-1611-4000 120 VAC K t/c 0 to 600°C Low Limit
Auto Reset
8A Relay Integral DIN Rail LV C6LZ 0000 0600 A 6, 8
146E-1611-4N00 120 VAC K t/c 32 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5KZ 0032 1112 A 2, 6, 8
146E-1611-4N00 120 VAC K t/c 0 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5LZ 0000 0600 A 2, 6, 8
146E-1611-4P00 120 VAC K t/c 32 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5KZ 0032 1112 A 2, 6, 8
146E-1611-4P00 120 VAC K t/c 0 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5LZ 0000 0600 A 2, 6, 8
146E-1611-4S00 120 VAC K t/c 32 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5KZ 0032 1112 A 2, 6, 8
146E-1611-4S00 120 VAC K t/c 0 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5LZ 0000 0600 A 2, 6, 8
146E-1615-1000 120 VAC J t/c 315°C High Limit
Manual Reset
8A Relay Fixed DIN Rail LF C6HU 0315 AAAA A 6, 8
146E-1615-1000 120 VAC J t/c 600°F High Limit
Manual Reset
8A Relay Fixed DIN Rail LF C6HU 0600 AAAA A 6, 8
146E-1615-2000 120 VAC J t/c 315°C Low Limit
Manual Reset
8A Relay Fixed DIN Rail LF C6HY 0315 AAAA A 6, 8
146E-1615-2000 120 VAC J t/c 600°F Low Limit
Manual Reset
8A Relay Fixed DIN Rail LF C6HY 0600 AAAA A 6, 8
146E-1615-3000 120 VAC J t/c 315°C High Limit
Auto Reset
8A Relay Fixed DIN Rail LF C6HW 0315 AAAA A 6, 8
146E-1615-3000 120 VAC J t/c 600°F High Limit
Auto Reset
8A Relay Fixed DIN Rail LF C6HW 0600 AAAA A 6, 8
146E-1615-4000 120 VAC J t/c 315°C Low Limit
Auto Reset
8A Relay Fixed DIN Rail LF C6HZ 0315 AAAA A 6, 8
146E-1615-4000 120 VAC J t/c 600°F Low Limit
Auto Reset
8A Relay Fixed DIN Rail LF C6HZ 0600 AAAA A 6, 8
146E-1618-1000 120 VAC J t/c 0 to 200°F High Limit
Manual Reset
8A Relay Integral DIN Rail LV C6HU 0000 0200 A 6, 8
146E-1618-1000 120 VAC J t/c -17 to 93°C High Limit
Manual Reset
8A Relay Integral DIN Rail LV C6JU -017 0093 A 6, 8
146E-1618-1N00 120 VAC J t/c 0 to 200°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0000 0200 A 2, 6, 8
146E-1618-1N00 120 VAC J t/c -17 to 93°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU -017 0093 A 2, 6, 8
146E-1618-1P00 120 VAC J t/c 0 to 200°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0000 0200 A 2, 6, 8
146E-1618-1P00 120 VAC J t/c -17 to 93°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU -017 0093 A 2, 6, 8
146E-1618-1S00 120 VAC J t/c 0 to 200°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0000 0200 A 2, 6, 8
146E-1618-1S00 120 VAC J t/c -17 to 93°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU -017 0093 A 2, 6, 8
146E-1618-2000 120 VAC J t/c 0 to 200°F Low Limit
Manual Reset
8A Relay Integral DIN Rail LV C6HY 0000 0200 A 6, 8
146E-1618-2000 120 VAC J t/c -17 to 93°C Low Limit
Manual Reset
8A Relay Integral DIN Rail LV C6JY -017 0093 A 6, 8
146E-1618-2N00 120 VAC J t/c 0 to 200°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HY 0000 0200 A 2, 6, 8
146E-1618-2N00 120 VAC J t/c -17 to 93°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JY -017 0093 A 2, 6, 8
146E-1618-2P00 120 VAC J t/c 0 to 200°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HY 0000 0200 A 2, 6, 8
146E-1618-2P00 120 VAC J t/c -17 to 93°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JY -017 0093 A 2, 6, 8
146E-1618-2S00 120 VAC J t/c 0 to 200°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HY 0000 0200 A 2, 6, 8
146E-1618-2S00 120 VAC J t/c -17 to 93°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JY -017 0093 A 2, 6, 8
146E-1618-3000 120 VAC J t/c 0 to 200°F High Limit
Auto Reset
8A Relay Integral DIN Rail LV C6HW 0000 0200 A 6, 8
146E-1618-3000 120 VAC J t/c -17 to 93°C High Limit
Auto Reset
8A Relay Integral DIN Rail LV C6JW -017 0093 A 6, 8
146E-1618-3N00 120 VAC J t/c 0 to 200°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HW 0000 0200 A 2, 6, 8
146E-1618-3N00 120 VAC J t/c -17 to 93°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JW -017 0093 A 2, 6, 8
146E-1618-3P00 120 VAC J t/c 0 to 200°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HW 0000 0200 A 2, 6, 8
146E-1618-3P00 120 VAC J t/c -17 to 93°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JW -017 0093 A 2, 6, 8
Watlow Controls 3/30/2005 Page 38