Series 146
Series 146
Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146D-1K1D-2100 120 VAC K t/c 0 to 1250°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV C6LY 0000 1250 A
6, 8
146D-1K1D-2200 120 VAC K t/c 32 to 2282°F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV C5KY 0032 2282 A
2, 6, 8
146D-1K1D-2200 120 VAC K t/c 0 to 1250°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV C5LY 0000 1250 A
2, 6, 8
146D-1K1D-3100 120 VAC K t/c 32 to 2282°F High Limit
Auto Reset
3A Relay Integral DIN Rail LV C6KW 0032 2282 A
6, 8
146D-1K1D-3100 120 VAC K t/c 0 to 1250°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV C6LW 0000 1250 A
6, 8
146D-1K1D-3200 120 VAC K t/c 32 to 2282°F High Limit
Auto Reset
3A Relay Remote DIN Rail LV C5KW 0032 2282 A
2, 6, 8
146D-1K1D-3200 120 VAC K t/c 0 to 1250°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV C5LW 0000 1250 A
2, 6, 8
146D-1K1D-4100 120 VAC K t/c 32 to 2282°F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV C6KZ 0032 2282 A
6, 8
146D-1K1D-4100 120 VAC K t/c 0 to 1250°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV C6LZ 0000 1250 A
6, 8
146D-1K1D-4200 120 VAC K t/c 32 to 2282°F Low Limit
Auto Reset
3A Relay Remote DIN Rail LV C5KZ 0032 2282 A
2, 6, 8
146D-1K1D-4200 120 VAC K t/c 0 to 1250°C Low Limit
Auto Reset
3A Relay Remote DIN Rail LV C5LZ 0000 1250 A
2, 6, 8
146D-1K1F-1100 120 VAC K t/c 32 to 2282°F High Limit
Manual Reset
3A Relay Integral DIN Rail LV C6KU 0032 2282 A
6
146D-1K1F-1200 120 VAC K t/c 32 to 2282°F High Limit
Manual Reset
3A Relay Remote DIN Rail LV C5KU 0032 2282 A
2, 6
146D-1K1F-2100 120 VAC K t/c 32 to 2282°F Low Limit
Manual Reset
3A Relay Integral DIN Rail LV C6KY 0032 2282 A
6
146D-1K1F-2200 120 VAC K t/c 32 to 2282°F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV C5KY 0032 2282 A
2, 6
146D-1K1F-3100 120 VAC K t/c 32 to 2282°F High Limit
Auto Reset
3A Relay Integral DIN Rail LV C6KW 0032 2282 A
6
146D-1K1F-3200 120 VAC K t/c 32 to 2282°F High Limit
Auto Reset
3A Relay Remote DIN Rail LV C5KW 0032 2282 A
2, 6
146D-1K1F-4100 120 VAC K t/c 32 to 2282°F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV C6KZ 0032 2282 A
6
146D-1K1F-4200 120 VAC K t/c 32 to 2282°F Low Limit
Auto Reset
3A Relay Remote DIN Rail LV C5KZ 0032 2282 A
2, 6
146D-1K2C-1100 120 VAC K t/c 16 to 149°C High Limit
Manual Reset
3A Relay Integral DIN Rail LV C6LU 0016 0149 A
6
146D-1K2C-1200 120 VAC K t/c 16 to 149°C High Limit
Manual Reset
3A Relay Remote DIN Rail LV C5LU 0016 0149 A
2, 6
146D-1K2C-2100 120 VAC K t/c 16 to 149°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV C6LY 0016 0149 A
6
146D-1K2C-2200 120 VAC K t/c 16 to 149°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV C5LY 0016 0149 A
2, 6
146D-1K2C-3100 120 VAC K t/c 16 to 149°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV C6LW 0016 0149 A
6
146D-1K2C-3200 120 VAC K t/c 16 to 149°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV C5LW 0016 0149 A
2, 6
146D-1K2C-4100 120 VAC K t/c 16 to 149°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV C6LZ 0016 0149 A
6
146D-1K2C-4200 120 VAC K t/c 16 to 149°C Low Limit
Auto Reset
3A Relay Remote DIN Rail LV C5LZ 0016 0149 A
2, 6
146D-1K2D-1100 120 VAC K t/c 60 to 300°F High Limit
Manual Reset
3A Relay Integral DIN Rail LV C6KU 0060 0300 A
6, 8
146D-1K2D-1100 120 VAC K t/c 16 to 149°C High Limit
Manual Reset
3A Relay Integral DIN Rail LV C6LU 0016 0149 A
6, 8
146D-1K2D-1200 120 VAC K t/c 60 to 300°F High Limit
Manual Reset
3A Relay Remote DIN Rail LV C5KU 0060 0300 A
2, 6, 8
146D-1K2D-1200 120 VAC K t/c 16 to 149°C High Limit
Manual Reset
3A Relay Remote DIN Rail LV C5LU 0016 0149 A
2, 6, 8
146D-1K2D-2100 120 VAC K t/c 60 to 300°F Low Limit
Manual Reset
3A Relay Integral DIN Rail LV C6KY 0060 0300 A
6, 8
146D-1K2D-2100 120 VAC K t/c 16 to 149°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV C6LY 0016 0149 A
6, 8
146D-1K2D-2200 120 VAC K t/c 60 to 300°F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV C5KY 0060 0300 A
2, 6, 8
146D-1K2D-2200 120 VAC K t/c 16 to 149°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV C5LY 0016 0149 A
2, 6, 8
146D-1K2D-3100 120 VAC K t/c 60 to 300°F High Limit
Auto Reset
3A Relay Integral DIN Rail LV C6KW 0060 0300 A
6, 8
146D-1K2D-3100 120 VAC K t/c 16 to 149°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV C6LW 0016 0149 A
6, 8
146D-1K2D-3200 120 VAC K t/c 60 to 300°F High Limit
Auto Reset
3A Relay Remote DIN Rail LV C5KW 0060 0300 A
2, 6, 8
146D-1K2D-3200 120 VAC K t/c 16 to 149°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV C5LW 0016 0149 A
2, 6, 8
146D-1K2D-4100 120 VAC K t/c 60 to 300°F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV C6KZ 0060 0300 A
6, 8
146D-1K2D-4100 120 VAC K t/c 16 to 149°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV C6LZ 0016 0149 A
6, 8
Watlow Controls 3/30/2005 Page 6