Watlow Series 96 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Watlow Series 96 herunter. Watlow Series 96 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 72
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
0600-0002-0002 Rev G Made in the U.S.A.
July 2005 $15.00
Supersedes: 0600-0002-0002 Rev F
Users Manual
Registered Company
Winona, Minnesota USA
ISO 9001
TOTAL
3 Year Warranty
CUSTOMER
SATISFACTION
Series 96
1/16 DIN Temperature Controller
with Custom Toolbar (patented)
User Levels:
• New User ....................................................... go to page 1.1
• Experienced User .......................................... go to page 2.1
• Expert User .................................................... go to page 2.1
Installers:
• Installation ...................................................... go to page 2.1
• Wiring .............................................................go to page 3.1
1241 Bundy Blvd., P.O. Box 5580, Winona, Minnesota USA 55987-5580
Phone: (507) 454-5300, Fax: (507) 452-4507 http://www.watlow.com
U.S. English
Seitenansicht 0
1 2 3 4 5 6 ... 71 72

Inhaltsverzeichnis

Seite 1 - Series 96

0600-0002-0002 Rev G Made in the U.S.A.July 2005 $15.00Supersedes: 0600-0002-0002 Rev FUser’s ManualRegistered Company Winona, Minnesota USA ISO 9001

Seite 2 - Your Feedback

3.4 Wiring Watlow Series 96Output 1 WiringFigure 3.4a – AC Outputs•Electromechanical relay withoutcontact suppression96 _ _ - D _ _ _ - _ _ _ _Form

Seite 3 - Table of Contents

Watlow Series 96 Wiring 3.5Output 2 WiringFigure 3.5a – AC Outputs•Electromechanical relay without contact suppression96 _ _ - _ D _ _ _ - _ _ _ _

Seite 4 - Overview

3.6 Wiring Watlow Series 96Output 3 WiringFigure 3.6 – AC OutputsElectromechanical relay without contact suppression96 _ _ - _ _ D_ - _ _ _ _Form C,

Seite 5 - Installation

Watlow Series 96 Wiring 3.7Output 4 WiringFigure 3.7a – AC OutputsElectromechanical relay without contact suppression96 _ _ - _ _ _ D - _ _ _ _Form

Seite 6

3.8 Wiring Watlow Series 96Figure 3.8a – EIA-232 to EIA-485 ConversionB&B Converter (B&B Electronics Manufacturing Company, [815] 433-5100).

Seite 7 - Chapter Three

Watlow Series 96 Wiring 3.9Wiring ExampleFigure 3.9 – System wiring example.1120VÅ (ac)L1L2276451 212(+)(-)313211415161721CR18high-temperature light

Seite 8 - Input 1 Wiring

4.1 Navigation and Software Watlow Series 964Chapter FourNavigation and SoftwareKeys and DisplaysThis chapter explains keys, displays and navigation

Seite 9 - Input 2 Wiring

Navigating the Series 96Choose a page (Operation, Setup or Factory) and press its key sequence. The page appearsin the lower display.Press ¯ or ¿ to f

Seite 10 - Output 1 Wiring

4.3 Navigation and Software Watlow Series 96Program Menu*(see pg. 7.1)The Factory Page includes calibrationparameters that are not necessary forever

Seite 11 - Output 2 Wiring

Basic navigation for new usersUse this example task to learn how to use the keys and displays. For more informationabout the control features availabl

Seite 12 - Output 3 Wiring

Safety InformationWe use note, caution and warning symbols throughout this book to draw yourattention to important operational and safety information.

Seite 13 - Output 4 Wiring

ChapterFiveFeaturesThe System5.1 Features Watlow Series 965Custom Menu (patented)The Custom Menu provides you with a shortcut tomonitor, tune or cha

Seite 14 - +12VÎ(dc)

Watlow Series 96 Features 5.2Auto-tuneAuto-tuning allows the controller to explore theresponsiveness of the system to determine an effec-tive set of

Seite 15 - Wiring Example

5.3 Features Watlow Series 96InputCalibration OffsetCalibration offset allows a device to compensate foran inaccurate sensor, lead resistance or oth

Seite 16 - Chapter Four

Watlow Series 96 Features 5.4Range Low and Range HighThe controller constrains the set point to a valuebetween range high and range low. Range high

Seite 17 - Navigating the Series 96

5.5 Features Watlow Series 96Retransmitting a Remote Set PointThe retransmit feature allows an output to retrans-mit an analog signal that can serve

Seite 18 - Series 96 Software Map

Watlow Series 96 Features 5.6Proportional plus Integral (PI) ControlThe droop caused by proportional control can be cor-rected by adding integral (r

Seite 19 - Configure the controller

5.7 Features Watlow Series 96Proportional plus Integral plus Derivative(PID) ControlUse derivative (rate) control to minimize the over-shoot in a PI

Seite 20 - Features

Watlow Series 96 Features 5.8Burst FireBurst firing provides even output power with thelowest level of noise generation (RFI). Burst fire isthe pref

Seite 21 - Power Limit

Alarms5.9 Features Watlow Series 96An alarm takes some action, usually notifying an operator, when the process temperature leaves a definedrange. A

Seite 22 - Sensor Selection

System Errors (error number in top display, error message in bottom display)Modbus Register #209 r; (values in parenthesis below).Refer to appendix, p

Seite 23 - Event Input

Chapter 1: Overview . . . . . . . . . . . . . . .1.1Chapter 2: Installation . . . . . . . . . . . . . .2.1Chapter 3: Wiring . . . . . . . . . . . .

Seite 24 - Control Methods

Input Errors (error number in top display, percent output in bottom display)Modbus Register #101 r; (values in parenthesis below).[Err1] (1) Error 1 i

Seite 25 - Proportional Control

Watlow Series 96 Parameters 6.1Chapter SixParameters6Home PageThe resting-state display shows one of the following sets of data, depending on contro

Seite 26 - Dead Band

6.2 Parameters Watlow Series 96Operations Page / Monitor MenuOperations PageThe Operations Page contains five menus:Active if Auto-Manual OperationM

Seite 27 - Ramp to Set Point

Active if Propband 1(PID 1 Menu)is not set to [```0], Units Type(Global Menu) is set to [``US]and Operations Page Lock(Lockout Menu) is not set to[hid

Seite 28 - Alarm Set Points

Active if output 2 is present (not96 _ _-_ A _ _-_ _ _ _), one out-put is set to [heat], another isset to [COOL] and OperationsPage Lock (Lockout Menu

Seite 29 - Open Loop Detect

Active if Propband 2 (PID 2Menu) is not set to [```0],Burst 2 (PID 2 Menu) is set to[``no], output 2 is not a pro-cess (not 96 _ _ - _ F _ _-_ _ _ _)a

Seite 30 - Communications

NOTE: For more information about how parameter settings affect the controller’s operation, see Chapter Five, Features.Active if Output 3 (Output 3Menu

Seite 31 - Parameters

****Output 4 parameters cannot be changed with the Modbus interface.Active if Output 4 (Output Menu4) is set to [``AL] (Alarm),Alarm Sides 4 (Output M

Seite 32 - Operations Page

*These parameters are added if the ramping software option has been ordered (96 _ _ - _ ___- AA __ ) .**These parameters are removed if the ramping so

Seite 33 - Operations Page / PID 1 Menu

Active if input 2 hardware is pre-sent (96 _1 _-_ _ _ _ -_ _ _ _)and Setup Page Lock (LockoutMenu) is not set to [hide].611 r/w[`OFF] (0)[`OFF] off: (

Seite 34

11.1 Overview Watlow Series 96Chapter OneOverviewIntroductionWith one universal input, a second auxiliary input and four outputs, the Series 96 can

Seite 35 - Operations Page / PID 2 Menu

Active if input 2 hardware is pre-sent (96 _1 _-_ _ _ _ -_ _ _ _)and Input 2 (Input 2 Menu) isset to [E`In] (Event Input)and Setup Page Lock (LockoutM

Seite 36 - Operations Page / Alarm Menu

Active if output 2 is present, butis not process type ( not 96 _ _-_ A _ _-_ _ _ __ or 96 _ _-_ F_ _-_ _ _ _), Output 2 (Output 2Menu) is set to [``AL

Seite 37

NOTE: For more information about how parameter settings affect the controller’s operation, see Chapter Five, Features.Active if output 2 is present, b

Seite 38 - Setup Page

Active if output 3 is present (96 __-_ _ D _-_ _ _ _), Output 3(Output 3 Menu) is set to[``AL] (Alarm) and SetupPage Lock (Lockout Menu) isnot set to

Seite 39 - [Inp2] Input 2 Menu

NOTE: For more information about how parameter settings affect the controller’s operation, see Chapter Five, Features.Active if output 4 is equipped f

Seite 40 - Setup Page / Input 2 Menu

Active if output 4 is equipped forretransmit (96 _ _-_ _ _ M-_ _ __), Analog Output 4 (Output 4Menu) is set to [`OFF] andSetup Page Lock (LockoutMenu)

Seite 41 - Setup Page / Output 2 Menu

*These parameters are added if the ramping software option has been ordered (96 _ _ - _ ___- AA __ ) .**These parameters are removed if the ramping so

Seite 42

Added if ramping version of thecontroller is selected (96__-____-AA__).1208 r/w[``ti] (0)[``ti] time based (0) [rate] rate based (1)[ptyp] Program Typ

Seite 43 - Setup Page / Output 3 Menu

Active: Always1400-1415r/w[``p1]:[A-m](OperationMode)[``p2]:[`Aut](Auto-tune)[``p3]:[Pcnt](PercentPower)[``p4]:[CAL1](CalibrationOffset)[``p5] to[`p16

Seite 44 - Setup Page / Output 4 Menu

Active: Always1301 r/w[chng] (1)[hide] hide (0)[chng] change (1)[read] read only (2)[Oper] Operations PageMode LockSet the OperationsPage lockout leve

Seite 45

Chapter TwoInstallationFigure 2.1 – Series 96 multiple panel cutout dimensions.NOTE: Measurements between panel cutouts are the minimum recommended.Fo

Seite 46 - Setup Page / Global Menu

Active: Always3 rnone0 to 9999[Soft] Software ID Num-berRead the software IDnumber.Active: Always2 rnone0 to 9999[`Sn2] Serial Number 2Read the last f

Seite 47

Active: Always1707 rnone-199.9 to 199.9(-1999 to 1999)[hres] High ResolutionDisplays high reso-lution input value.Active: Must be in [dIag] mode1513 r

Seite 48 - Factory Page

NOTE: For more information about how parameter settings affect the controller’s operation, see Chapter Five, Features.NOTE: Complete calibration menus

Seite 49 - Setup Page / Lockout Menu

Watlow Series 96 Ramping 7.1Chapter SevenRamping7Program Menu PromptsEntering the Program Menu: Press the ‰Advance key to enter the Program Menu whi

Seite 50

7.2 Ramping Watlow Series 96Active if hardware is present forOutputs 2, 3 or 4 and the pa-rameters are set to [Eunt].Selecting a number to appear wi

Seite 51 - [dIag] mode

Always displayed in this menu.See p. 7.7[`Off] (-32768)[`Off] (-32768)[```O] to [``99][wde] Wait-for DeviationValueThe program will notbegin to decrem

Seite 52

How to Navigate with the Ramping Menus*Exit menu refers to returning back to the display of process value in the upper display and active setpoint val

Seite 53 - Chapter Seven

The Pre-run and Run menu prompts are only visiblewhen in the Pre-Run or Run mode.The Pre-run mode is entered by pressing theˆInfinity key one time whi

Seite 54 - [stpt] Set Point Step

NOTE: For more information about how parameter settings affect the controller’s operation, see Chapter Five, Features.Jump-loopsThe Series 96 can jump

Seite 55 - [soaH] Soak Step

Watlow Series 96 Ramping 7.7Register Register 106 (Alarm 2 Status)Register 110 (Alarm 3 Status)0 No Alarm Exists1 Alarm High State2 Alarm Low State

Seite 56

2.2 Installation Watlow Series 96See the figure below. Make sure that you cannot move the controller back and forth inthe cutout. If you can, you do

Seite 57 - Resume a Profile

A.1 Appendix Watlow Series 96AppendixATroubleshooting Alarms and Errors• Check comms setup menu and set to correctaddress.• Check comms setup menu a

Seite 58 - Event Input Functions

Watlow Series 96 Appendix A.2• Cycle power to unit. If problem persists,return unit to factory.• Cycle power to unit.• Cycle power to unit. If probl

Seite 59 - (Read and Write)

0 Model Number1 Serial Number 12 Serial Number 23 Software ID Number4 Software Revision5 Date of Manufacture9 Input 2 Hardware Enabled16 Output 1 Hard

Seite 60 - Appendix

Jim Boigenzahn Winona, Minnesota, USAName of Authorized Representative Place of IssueGeneral Manager September 2001Title of Authorized Representative

Seite 61 - set it to a

A.5 Appendix Watlow Series 96Output TypesOpen Collector/Switched DC• Open collector configuration:Maximum voltage 42VÎ (dc)Maximum current 200mAMaxi

Seite 62 - Special Modbus Functions

Watlow Series 96 Appendix A.6Communications• EIA/TIA-485 or EIA/TIA-232• Opto-isolated • ModbusTMRTU protocol• 1200, 2400, 4800, 9600, 19200 baud ra

Seite 63 - Declaration of Conformity

Ordering Information(2201)Series 969 6 ——– ————– ————Microprocessor-based 1/16DIN with universal input 1. Options include software, power supply, in

Seite 64 - Specifications

Watlow Series 96 Appendix A.8Index AAbort Set Point 6.11Address 6.16Alarm 2 High 6.6Alarm 2 Low 6.6Alarm 2 Type 6.11Alarm 3 High 6.7Alarm 3 Low

Seite 65 - Functionality Matrix

A.9 Appendix Watlow Series 96NNavigation and Software 4.1-4.4Raming menu 7.4OOn/Off control 5.5Open Loop Detect 5.10, 6.17Operations Page 4.2,

Seite 66 - Ordering Information

Watlow Series 96 Appendix A.10Prompt Index[1``1] Output Calibration 1, 1V [1``4] Output Calibration 1, 4mA [1`10] Output Calibration 1, 10V [1`20]

Seite 67 - Calibration Offset 5.3, 6.3

Chapter ThreeWiringInput-to-Output IsolationFigure 3.1a Isolation blocks.Power Wiring100 to 240VÅ (ac), nominal (85 to 264 actual) 96 A _ - _ _ _ _ -

Seite 68

Series 96 Software Map[``96] Process 1 Value[``96] [``96] Custom Menu**…[``P1]Home PageSet Point Value,Remote Set Point Value or Percent Output ValueS

Seite 69 - Prompt Index

Using the Manual Units Type [Unit] °C or °F [`C-F]Output 1 [Ot`1]Output 2 [Ot`2]Sensor Type [Sen1]Input 1 [In`1]Range High 1 [rh`1]Range Low [rL`1]De

Seite 70

Using the ManualWatlow Series 96 User’s ManualWatlow Winona, 1241 Bundy Blvd., P.O. Box 5580, Winona, MN USA 55987-5580,Phone: (507) 454-5300, Fax:

Seite 71 - Table 3.2 — Set up

3.2 Wiring Watlow Series 96NOTE:Successful installationrequires five steps:• Choose the controller’shardware configurationand model number(Appendix)

Seite 72 - How to Reach Us

Watlow Series 96 Wiring 3.3çWARNING:To avoid damage toproperty and equipment,and/or injury of loss oflife, use National ElectricCode (NEC) standardw

Kommentare zu diesen Handbüchern

Keine Kommentare